Parameter
Input Voltage: 100-240V, 50/60Hz
Output Voltage: V1:36V(Master board), V2:12V(cooling fan) , V3:380V(lamp)
Power consumption: 300 W
Power supply: 400W
Light source: OSRAM SIRIUS HRI 231W (2500 hours)
Color temperature: 7900K
Diameter of optic lens: 136mm
Beam angle: 2.°
Color wheel: 1 color wheel, 14 fixed colors plus white, two-way rainbow effect
Static Gobo: 17 gobos plus 1 white circle
Prism: equipped with 12 prisms and 16+16 double-layer prisms, the two prisms
can be stacked and rotated in both directions
DMX Channel: 18CH
Operate mode: DMX512, Auto, master/slave, RDM
Electric focusing system
Outstanding strobe effect with variable speed
0-100% smooth dimming
2.8 inch LCD display
Power Outlet: Power Connector Input/Output
Signal Outlet: standard 3 Pin XLR socket(can customized 5 pin XLR socket)
Installation: 2x fast lock
Fixture size: 338x256x512mm
Net weight: 16.6KG
Features:
B230, color temperature up to 7900K, combined with the rainbow effect of two-way rotation, can produce excellent color macro; The beam angle is 2 °, the beam is straight and sharp, equipped with 12 prism 16+16 prism that can be superimposed and rotated to easily achieve the stage atmosphere rendering effect; Excellent performance
-
Effect Wheels


-
Size


-
Light Source
OSRAM SIRIUS HRI 231W
Because of its high internal pressure, there might be a risk that the Discharge lamp would explode during operation. The lamp emits intense UV radiation which is harmful to the eyes and skin. The high luminance of the arc can cause severe damage to the retina if you take a close look at the lamp.
To protect the lamp, always turn off the lamp first (via control panel or DMX controller) and let the unit run at least five minutes to cool down before switching off the mains supply. Never handle the lamp or luminary when it is hot.
Do not touch the bulb with bare hands. If this happens, clean the lamp with denatured alcohol and wipe it with a lint free cloth before installation.
The lamp generates UV radiation. Never operate the lamp without appropriate shielding.
When lighting up, the lamp operates at high pressure and there is a slight risk of arc tube rupture. The risk increases with age, temperature and improper handling of the lamp. Do not use the lamp longer than its lifespan.
Make sure the lamp is located in the center of the reflector for the best projection.